6-5Ricoh Embedded Software Architecture (ESA) Device Client v1.4 Installation and Integration Guide
Section 6: Optional configuration
Modifying memory sizes of Heap, Stack and System
Memory
1 Walk up to the Ricoh device and click User Tools > Counters.
2 Select Extended Feature Settings.
3 In the Extended Feature Settings Menu select Extending Feature Setting.
4 Select the Administrator Tools tab.
5 Select Heap/Stack Size Settings. A dialog open displaying heap, stack and total memory sizes.
6 Modify the heap and stack sizes or restore them to the default values as needed.
Note System memory sizes cannot be changed.
Enabling Job Build
Note The following configuration should be performed every time a user needs to use set the Job Build mode
on.
1 Navigate to:
C:\Program Files\omtool\Omtool Server\WebAPI\OmtoolWebAPI\Scripts\
2 Open Configuration.Ricoh.xml for editing.
3 Locate the <DeviceScanSettings> node and then the <ScanSourceMode> node.
4 Modify the value for the <ScanSourceMode> node as shown below.
<ScanSourceMode>SADF</ScanSourceMode>
5 After you finish making the necessary changes, save the file.
6 Restart the World Wide Web Publishing service.
7 Stop and restart the OmtoolXlet application at the device.
Now the user will be prompted to add more pages when scanning.