7-2 Other
Events generated by the database
Event Cause and Action
The message "Warning
capacity of SQL database
exceeded!" appears.
The message "System
suspension capacity of SQL
database exceeded!"
appears.
These messages appear when the
SQL database’s capacity has
been exceeded.
If either the Job or Access log, or some combination of them
exceeds 3.6 GB, the SQL database will consider itself full and the
database will stop accepting more data. This is the result of a
limitation in
SQL.
<Suggested Actions>
Use the [System Log for Device Log Collection] (p.106 “System
Log for Device Log Collection”) to check the SQL database’s
current capacity and, if necessary, delete unnecessary logs in
[Log Management] [Service Settings] (
p.74 “Log Management
Service Settings”) - [Log Batch Deletion...].
Also, shorten the storage period in [Log Management Service
Settings]
- [Specify Log Storage Period...] in order to reduce the amount of
data in the MSDE database.