5-1-15 Device Log Transfer Settings
This function changes the settings used to determine if a device sends its Job Logs and Access Logs to
the RCGSP DB for unified storage purposes. It also identifies the current status of log transfer settings
per device.
No. Process Protocol Port Access Limit Note
1 Collect information.
HTTP/SOAP
or
HTTPS/SOAP
80/443
Requires:
1.User Name
2.Password
Collects the following
information:
1.Capability
ex. Max length of Login
Name, Password policy,
etc.
2.Current Setting
2
Send setting
information
HTTP/SOAP
or
HTTPS/SOAP
80/443
Need to set
below:
1.User Name
2.Password
Sets the following
information:
1.Setting value
3 Perform Reset
HTTP/SOAP
or
HTTPS/SOAP
80/443
Need to set
below:
1.User Name
2.Password
Performs a “Reset”
operation if necessary.
Items 1-3 repeat as
required.
5-1-16 User Counter Collection
RCGSP server can collect user counter information from registered printers. User counters keep track of
how printers are used on a per-user basis. Because these counters can require a large amount of disk
space, collection is disabled by default. User counter information is not viewable from the Remote
Communication Gate S web interface. The "UserCounterExport.exe" command line tool is used to
export the data.
No. Process Protocol Port Access Limit Note
1 Collect information
HTTP/SOAP
or
HTTPS/SOAP
80/443
Requires:
1.User Name
2.Password
Collects the following
information:
1.Capability
ex. Max length of Login
Name, Password policy,
etc.
2.User Counter
Vista de pagina 17