Does SURETE support UPS systems?
What type of switching power supply is recommended to connect with SURETE?
Is there any special attention needed to be paid in spec while installing ATX power supply?
What power management features does the SURETE support?
Which model of APC Smart series UPS can be connected to SURETE?
How soon do we need to replace the broken cooling fan before it may cause system overheated?
Does SURETE support UPS systems?
Yes, SURETE can integrate with UPS power management via smart signaling as well. SURETE can connect APC Smart serial UPS in
current state.
For detail model inquiry, please visit APC web site Smart-UPS section.
What type of switching power supply is recommended to connect with SURETE?
We strongly recommend you to install ATX switching power supply with the SURETE because the features of controlling ATX
power supply have been included in the hardware and firmware of the SURETE.
Is there any special attention needed to be paid in spec while installing ATX power supply?
It is strongly recommended to use ATX power supply unit with more than 350 watt for SURETE. Especially, the peak current of 12
Voltage needs to be over 22 A. For instance, the spin-up current of HDD will be 2800 mA when 8 HDDs are connected with
SURETE. The peak current can reach over 22.4 A (2800 mA X 8). To avoid the situation that HDD can't be mounted, it is
suggested to use power supply of recommended spec.
What power management features does the SURETE support?
The SURETE has supported the following outstanding features on power management if an ATX power supply is engaged. For
example, "UPS control to shutdown", "safe shutdown", "schedule shutdown", and "schedule power ON".
Which model of APC Smart series UPS can be connected to SURETE?
You can go to www.apc.com under product / UPS. You will see Smart-UPS and Smart-UPS XL series. This is what SURETE support
because they use the same protocol. The model changes as time goes. Customers can also go this site for exact model they need.
How soon do we need to replace the broken cooling fan before it may cause system overheated?
We have the redundant hot-swap cooling fans installed in the back of system (in model SURETE 8100T and 8100R). Actually only
one cooling fan is good enough to handle the heat issue of system. System still can normally function when one of cooling fans is
malfunctioning and the other is functioning. So you will have enough time to do hot-swap with the broken one. But system needs
to be safely shutdown as soon as you can if both cooling fans are dead.